Internal Test Software
The following diagnostic tests are available using the thumbwheels on your Source Four
Revolution fixture. To run a test, set the address to the desired test (tests may be run at any
time). The green LED will blink rapidly to indicate the fixture is in self-test mode and the
fixture will not respond to incoming DMX signal. To return the fixture to DMX operation, set
the thumbwheel back to a valid DMX start address.
Test Description Address Notes or Test Parameter (#)
HOLD 800
All open, Pan & Tilt @ 50%, Intensity @ 75% 8 0 1
SLOW fade all from 0-100% 8 0 2 20 seconds; continuous cycle.
MED fade all from 0-100% 8 0 3 10 seconds; continuous cycle.
FAST fade all from 0-100% 8 0 4
Bounce; some attributes may not complete their full
range of motion.
16 predefined cues run sequentially 8 0 5 5 seconds between cues.
Pan and Tilt motors disabled 8 0 6 NOTE: Cycle power to return to normal operation.
Bypass Calibration 8 0 7 Start-up at this address to skip calibration.
Fade parameters 0-100%, Intensity @ 8 0 8
Bounce; some attributes may not complete their full
range of motion.
HOLD 809
Dimmer (tests 815-819 do not apply) 8 1 #
Use the parameter numbers below in the (#) position
of the test address to change the behavior of the
tests. Example: test 825 moves the Pan motor from
end stop to end stop at a slow speed. Test 826
performs the same movement, but at medium speed.
Pan 82#
Tilt 8 3 #
Front Bay (Iris or Wheel modules) 8 4 #
Rear Bay (Iris or Wheel modules) 8 5 #
Scroller 8 6 #
0 = HOLD
Wheel Function (operates both bays) 8 8 #
1 = Increment (0-100%)
Wheel Index/Rotate (operates both bays) 8 9 #
2 = Decrement (100-0%)
Shutter #1 In/Out 9 0 #
3 = HOLD
Shutter #1 Rotate 9 1 #
4 = Invert (if on, fade to 0, if off, fade to full)
Shutter #2 In/Out 9 2 #
5 = SLOW fade from 0-100%, continuous cycle
Shutter #2 Rotate 9 3 #
6 = MED fade from 0-100%, continuous cycle
Shutter #3 In/Out 9 4 #
7 = FAST fade from 0-100%, continuous cycle
Shutter #3 Rotate 9 5 #
8 = Incremental fade from 0-100% of selected in 10%
increments in 1 second timing, continuous cycle
Shutter #4 In/Out 9 6 #
Shutter #4 Rotate 9 7 #
9 = Incremental fade from 0-100% of attribute in 25%
increments in 2 second timing, continuous cycle
Rotate All Shutters 9 8 #
Lenses and Internal Media Frame 8 7 #
0 = HOLD
1 = Increment Zoom (0-100%)
2 = Decrement Zoom (100-0%)
3 = HOLD
4 = Increment Focus (0-100%)
5 = Decrement Focus (100-0%)
6 = HOLD
7 = IMF In/Out (toggles state of IMF)
8 = Incremental Zoom from 0-100% in 10 second
timing, continuous cycle
9 = Incremental Focus from 0-100% in 10 second
timing, continuous cycle